| Stage
One |
| Sediment Filter, 5-Micron
Polyspun Cartridge, 2 1/2” dia. x 20" long |
 |
Stage
two |
Activated Carbon Block
Filter
5 Micron, 2 1/2” dia. x20" long |
 |
| Stage
Three |
Activated Carbon Block
Filter
5 Micron, 2 1/2” dia. x20" long |
 |
| booster
pump |
| Diaphragm pump with
pressure by-pass with low voltage DC motor |
 |
| Stage
Four |
| Up to four 100 GPD Hi-Flux
Reverse Osmosis Membranes |
 |
|
| In-Line post filter,
10-micron granular activated carbon, 2 1/2" dia., 14"
long (Option-replace carbon post filter with deionizer cartridge.)
|
|
| |
| Features |
•
•
•
•
•
|
Auto Shut-Off
valve (Conserves water)
Flow Restrictor – modified capillary
Long Reach, Non-airgap Faucet
Feed water connector – Threaded Inlet Adapter with Metal
Ballvalve Drain Clamp
3/8 Inch Flexible Polyethylene Tubing w/Quick Connect Fittings |
| |
|
Up to four high capacity RO
membranes are used in series to provide the required water rate.
It is supplied with a 14-gallon pressurized tank which holds
9-gallons of water. Two tanks may be used to increase the reserve
to 18-gallons. The RO technology removes an average of 95% of
the TDS. To further decrease the salt content, a de-ionizer
cartridge can be installed as a post-filter. The five stages
are described in the table below.
A booster pump is installed in the system to provide water pressure
of 85 psi to the membranes. To reduce wear on the pump, it is
installed after the the pre-filters. A pressure switch in the
line to the tank will turn on the pump when the tank pressure
is 25 psi, and off at 40 psi. and is also adjustable.
An optional stand can be provided. Made of powder coated steel,
it bolts to the underside of the bracket, providing a floor
standing unit.  |
| Specifications
Shipping Weight: 65-80 lb.
Dimension: 13 1/2" L x 7.5" W x 40" H
Tank 15 3/4" dia. x 22 1/2" H
Booster Pump: 24-36 volt DC flow through diaphram
pump with 110VAC/ 24-36VDC60hz transformer |
Conditions of Use
• Water Must be microbiologically
safe
• Temperature, 40 -100 degrees F
• pH Range, 3 to 11
• Feed pressure, 20 to 100 psig
• Maximum TDS, 1500 PPM
• Turbidity, less than 1.0 NTU ed
|
|

|
AVAILABLE OPTIONS
350 GPD clean water rate
250 GPD clean water rate
150 GPD clean water rate
Optional Floor Stand
Optional de-ionizing stage
|
PWM-350
PWM-250
PWM-150
add /FS
add /DI
|
Replacement
Filters
RO membrane |
Sediment
Carbon Block
Post Carbon
PWM-150
PWM-250
PWM-350 |
SF-4014
CF-4015 x 2
IF-4011
MH-4206 x 2
MA-4205 x 3
MA-4205 x 4 |
|